However, for USB Video devices, a constraint with UVC based cameras is that for Windows 10 19H1, custom camera drivers are not allowed. All UVC based cameras must use the inbox USB Video Class driver and any vendor extensions must be implemented in the form of a Device MFT. 3-in-1 Interface USB Drives. Dual-Interface USB Drives-iOS Devices. Dual-Interface USB Drives. Click the dropdown arrow next to Universal Serial Bus controllers. If you're using the Inateck hub, you'll see a Fresco Logic USB driver. Right-click the Fresco Logic USB driver. In this case, I'm doing the same thing on the ASMedia driver. Description: G:Dispositif de stockage de masse USB(SMI USB MEMORY BAR) Device Type: Mass Storage Device Protocal Version: USB 2.00 Current Speed: High Speed Max Current: 500mA USB Device ID: VID = 090C PID = 3259 Device Vendor: Silicon Motion,Inc. Device Name: SM3259AA MEMORY BAR Device Revision: 0100 Manufacturer: SMI Product Model: USB.

  1. Drivers Motion Lingo Usb Devices Free
  2. Drivers Motion Lingo Usb Devices Download
  3. Drivers Motion Lingo USB Devices
SimpleMotion V2 USB adapter.

SimpleMotion V2 USB adapter (SMV2USB or USB-SMV2) is a usb device that acts as a bridge between USB port and SimpleMotion V2 RS485 based field bus. By technology point of view USB-SMV2 is a USB to RS485 serial converter with RJ45 connector.

The device driver installation wizard will now open, click on “Next” to install the driver. Figure 1: Clicking “Next” starts the installation. A final window will open letting you know the driver was installed. Click on “Finish” to complete the installation. Figure 2: The completion of the driver installation.

SMV2USB is the recommended RS485 interface to connect SimpleMotion V2 based drives (such as Argon) to Granity configuration software.

Drivers[edit | edit source]

In most cases operating system detects the SimpleMotion V2 USB adapter as USB serial port and is able to install drivers automatically. However, if not download VCP (Virtual COM Port) drivers from this page. The recommended package for Windows is the setup executable (direct link).

Availability[edit | edit source]

Devices

The adapter is available for purchase at Granite Devices web shop.

Alternatives[edit | edit source]

Device with similar functionality can be built from commonly available parts. For guide, see DIY SimpleMotion V2 adapter.


Drivers

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.

Retrieved from 'https://granitedevices.com/w/index.php?title=SimpleMotion_V2_USB_adapter&oldid=4577'
-->

This topic shows you how to install the sensor driver on a development board, after you update the secondary system description table (SSDT) for the development board.

This topic uses the Sharks Cove development board and an ADXL345 accelerometer as a case study, to help explain the process of installing a sensor driver on a development board. So if you want to perform the tasks presented in this topic, you must first install an operating system on the Sharks Cove. For more information about how to do that, see Download kits and tools for Windows 10, and follow the instructions to install Windows 10.

After you finish installing the operating system on the Sharks Cove, See Build the sensor driver to learn how to build a driver in Microsoft Visual Studio. Then return here to continue.

The accelerometer is attached to the Sharks Cove via the I2C bus. Peripherals that are connected to the I2C bus are enumerated via the Advanced Configuration and Power Interface (ACPI). So the sample driver for the accelerometer was developed to support ACPI instead of Plug and Play.

To make the Sharks Cove's ACPI driver aware of the new device (the accelerometer) on the I2C bus, you must add information about the accelerometer to the SSDT on the Sharks Cove. This table describes the hardware resources and interrupt requirements for a hardware platform's devices, including attached peripherals like the accelerometer.

Before you begin

Before you start performing the tasks outlined below, please make sure that your Sharks Cove is set up as shown in the following image:

Retrieve and review the default SSDT

This section shows you how to use the ACPI Source Language (ASL) compiler to retrieve the factory default SSDT for the Sharks Cove, and then review it. You will also learn how to replace the default SSDT with an updated one.

  1. On your development computer, navigate to the following location to copy the ASL compiler:c:Program Files (x86)Windows Kits10Toolsx86ACPIVerify

  2. Copy the Asl.exe file, and save it to a flash drive.

  3. On the Sharks Cove, create a Tools folder in the root directory. Then Attach the flash drive to the Sharks Cove's USB hub, and copy the Asl.exe file to the Tools folder.

  4. Open a Command prompt window as an administrator, and enter the following commands:cdtoolsdirMake sure that the Asl.exe file is listed in the directory.

  5. Invoke the ASL compiler and create an ASL file by entering the following command:asl /tab=ssdt

  6. Make sure that the ASL file was created successfully by entering the following command:dir ssdt.asl

  7. Open the ASL file in Notepad by entering the following command:notepad ssdt.aslReview the ASL file, and notice that there are no references to the accelerometer, or the I2C bus.

  8. Close Notepad. Then enter the following command in the Command prompt window, to rename the ssdt.asl file.ren ssdt.asl ssdt-old.aslThen use the dir command to make sure that the file is now listed as ssdt-old.asl.

Drivers Motion Lingo Usb Devices Free

Update the default SSDT

Perform the following tasks to update the SSDT, and load it to replace the factory default version. The updated SSDT will be stored in a potion of memory called battery-backed RAM. So make sure that the button cell (battery) that came with your Sharks Cove is plugged into its socket.

  1. Copy the following updated SSDT and paste it into a new instance of Notepad.

  2. In Notepad, select File > Save As. Then select the Save as type dropdown box, and select All Files.

  3. In the File name box, type ssdt.asl, then select Save, and close Notepad.

  4. In the Command prompt window, use the dir command to make sure that you can see the default file now listed as ssdt-old.asl, and the new file listed as ssdt.asl.

  5. Compile the ssdt.asl file into a format that the Sharks Cove can understand by entering the following command:asl ssdt.asl

  6. Verify that the compiled file was successfully created in Step 3 by entering the following command:dir ssdt.amlYou should see the ssdt.aml file listed in the tools directory.

  7. Load the compiled file into battery-backed RAM by entering the following command:asl /loadtable ssdt.aml

Turn on testsigning

Before you install the sample sensor driver, you must turn on testsigning. Perform the following tasks to turn on testsigning. Perform the following steps to install the sensor driver via Device Manager.

  1. In the Command prompt window, enter the following command to see whether testsigning is already turned on.
    bcdedit /enum

  2. If you see a listing similar to the following, showing an entry for testsigning, with its value set to yes then skip to Step 5.

  3. If you need to turn on test signing, then enter the following command:bcdedit /set testsigning on

  4. Repeat Step 1 (in this exercise) to verify that the value of the testsigning system variable is now set to 'yes' in the Windows Boot Loader list.

  5. Restart the Sharks Cove. As the board restarts, hold the Volume-up button for about 2 seconds, to enter system setup (UEFI) window.

  6. In the UEFI window, select Device Manager > System Setup > Boot, and make sure that UEFI Security Boot is set to <Disable>.

  7. Save your changes and exit the UEFI window.

Install the sensor driver

There are four main methods for installing a driver on the Sharks Cove board:

  • Download the driver from a network source directly onto the Sharks Cove.
  • Develop the sensor driver on a host computer, with your Sharks Cove connected as a provisioned client. Then deploy the driver from the host computer to the Sharks Cove.
  • Copy the driver package to a flash drive and attach the flash drive to the Sharks Cove. Then use the devcon command from a Command prompt window to install the driver manually.
  • Copy the driver package to a flash drive and attach the flash drive to the Sharks Cove. Then install the driver manually via Device Manager.

For simplicity, we will use the last method in the preceding list. Perform the following steps to manually install the sensor driver via Device Manager.

You must connect your sensor to the Sharks Cove before you install the sensor driver. For information about how to modify the ADXL345 accelerometer breakout board from SparkFun, to get it to work with the sample sensor driver, see Prepare your sensor test board. And for information about how to connect the sensor breakout board to the Sharks Cove, see Connect your sensor to the Sharks Cove board.

  1. Make sure that the ADXL345 accelerometer is connected to the Sharks Cove J1C1 connector, then power up the Sharks Cove.

  2. Attach a flash drive with the sensor driver to the powered USB hub connected to the Sharks Cove. For example, this can be the flash drive onto which you saved the driver that you built by following the steps in Build the sensor driver.

  3. Open Device Manager, and look for an 'Unknown device' in the Other devices node with a yellow bang symbol against it (see the following screen shot).

  4. Select and hold (or right-click) the device with the yellow bang (listed as Unknown device), and select Update Driver Software, and select Browse my computer for driver software.

  5. Browse to the ADXL345 driver on the flash drive, then select Next. Follow the screen prompts to install the sensor driver.

  6. After the sample sensor driver is successfully installed, Device Manager displays the sensor as shown in the following screen shot.

Drivers Motion Lingo Usb Devices Download

For information about how to use Visual Studio to deploy a driver to a client computer (like the Sharks Cove), see Deploying a Driver to a Test Computer.

Drivers Motion Lingo USB Devices

After successfully installing the sample sensor driver, see Test your universal sensor driver for information about how to test a sensor.